| S.NO. |
DESCRIPTION |
| 1 |
SHELL ASSEMBLY |
| 2 |
FILTER |
| 3 |
FUEL PUMP |
| 4 |
FUEL OIL TANK |
| 5 |
BLOWER |
| 6 |
OIL PRESSURE GAUGE |
| 7 |
PHOTO RESISTOR |
| 8 |
BURNER |
| 9 |
PR.SWITCH |
| 10 |
PR.GAUGE |
| 11 |
MAIN STEAM VALVE |
| 12 |
BY PASS VALVE |
| 13 |
SAFETY VALVE |
| 14 |
TEMP.CONTROLLER |
| 15 |
NO WATER SWITCH |
| 16 |
F.W.PUMP |
| 17 |
ECONOMISER |
| 18 |
BLOW DOWN VALVE |
| 19 |
FLUE GAS TEMP.CONTROLLER |
| 20 |
SOFT WATER SERVICE TANK |
| 21 |
FUEL OIL TRANSFER PUMP |
|
| HOT WATER GENERATOR P&I DIAGRAM |
|
| |
PROFILE
VAPOMAX Steam Boilers ( Non-IBR in India),are available in vertical design. ranging from 50 Kg/Hr to 2000 Kg/Hr (Non-IBR 50 to 800 Kg/Hr). No certified Boiler attendent and no special boiler house are required. |
| |
DESIGN FEATURES
VAPOMAX is designed for high efficiency of 88 + 2 %
• Fully Automatic Operation, VAPOMAX runs ON-OFF automatically on steam requirement, hence consumes minimum fuel & gives best operating efficiency.
• Designed for high pressure saturated steam generation.
• Designed for easy operation & maintenance.
• All standard Indigenous parts, so easy availability of spares.
• Due to Coil type design & maximum safety features incorporated, there are no explosion hazards.
• The Burner of the boiler is adjusted to give a high CO2 content & a high degree of efficiency maintaining clean combustion, almost free of air pollutants.
• High thermal efficiency due to combustion air preheating and water preheating with economiser.
|
| |
INSTANT STEAM
VAPOMAX produces steam within three to four minutes from cold start. |
| |
INSTRUMENTATION, CONTROLS AND SAFETIES
VAPOMAX is a fully automatic boiler. In any abnormal conditions either due to oil, water or flame failure, VAPOMAX shuts off & gives an alarm, indicating fault on control panel. So we can easily rectify the fault. |
| |
AFTER SALES SERVICE
We train our customer's boiler operators for routine operation & preventive maintenance at the time of commissioning of boiler. Backed up by efficient & promt service & spares. |
| |
LOW INSTALLATION COSTS
COMPACT VERTICAL DESIGN saves valuable floor space compared to other types of boilers. Almost no special foundation required. |
| |
| NOTES :
THE THERMAL EFFICIENCY IS GUARANTEED IN OUR TEST BED WITH COMMERCIALLY CLEAN INTERNAL AND EXTERNAL HEATING SURFACES.
THE EFFICIENCY IS SUBJECT TO FUEL OIL AS PER LDO - IS:1460, FO - IS:1593 WITH SEDIMENT CONTENT NOT MORE THAN 0.04% BY WEIGHT, VISCOSITY NOT MORE THAN 1500 SEC. REDWOOD No. 1 AT 37.8 O C (100 O F) AND NO CONRADSON CARBON. NCV of HSD-10,500 Kcal/Kg. LDO-10,200 Kcal/Kg. FO-9,650 Kcal/Kg.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. |
|
|
|
 |
| |
|
|
|
| |
|
|